Colorectal cancer (CRC) is one of the leading causes of cancer death worldwide. Current methods of detecting CRC can be invasive, such as colonoscopies, or non-invasive, such as the faecal occult blood test (FOBT). Although these screening tests have helped to reduce mortality, their performance is not optimal. The FOBT has a substantial number of false negatives and as a consequence a significant number of missed diagnoses of CRC. In addition, a significant percentage of healthy participants who are screened in the population receive a false positive result, which in turn leads to the unnecessary use of colonoscopies. Colonoscopies are an invasive technique, with a risk of complications (bleeding or perforation) as well as a high cost.
There are multiple publications that have provided studies that relate certain biomarkers, some of them volatile organic compounds (VOCs), with the probability of a subject suffering from CRC through different methods. However, none of them have so far provided a method, which is fast, reliable, economical and with high sensitivity, to detect and quantify VOCs that can be useful as biomarkers and at the same time allow the development of a screening method that can reduce or eliminate false positives and false negatives in the detection of CRC.
In this sense, a Spanish research group has developed a device adapted for the qualitative and quantitative analysis of VOCs) in solid and/or semi-solid samples, which consists of the following three elements: a headspace adsorptive magnetic extraction device, a thermal desorption system coupled to a gas chromatograph-mass spectrometer, and, a mass spectrometer that provides qualitative and quantitative analysis of VOCs (Figure 1).
The headspace adsorptive magnetic extraction device allows the volatilisation of VOCs from a sample, subjected to a certain temperature. The volatile compounds in the headspace are subsequently retained in an adsorbent trap, which is then desorbed and injected for separation and detection by gas chromatography-mass spectrometry.
This apparatus allows the extraction, identification and quantification of VOCs (P-cresol, 1H-indol, 3(4H)-dibenzofuranone or tetrahydrofolate) from stool samples, known as biomarkers in subjects suffering from CRC, or in subjects who are predisposed to suffering from CRC, to provide a prognosis of the subject's condition or to provide a negative prognosis.
Therefore, this device can be used to extract and perform accurate, simple, sensitive and effective analysis of VOCs for application as a non-invasive screening test for CRC.
The research group is looking for analytical instrumentation manufacturers or Medical diagnòstic laboratories interested in acquiring this technology for commercial exploitation through patent licensing agreements. The company should be responsible for the development of the commercial prototype, the validation of the technology, and its introduction into the market. The university will be ready to provide technical assistance in each step, if required.
However, the research group would be also interested in establishing technical cooperation agreements to further develop the laboratory-scale method, to find new applications or to adapt it to the company’s needs. The goal of this type of collaboration would be increasing the technology readiness level for a future commercial exploitation of the patent. The university would offer its support based on their know-how; while, the partner sought would provide its expertise to help improve this invention. The university would offer this partner a preferential option to acquire this technology in exclusivity.
Advantages & innovations
The main innovative aspect of the technology is the fact that, until now, 3(4H)-dibenzofuranone had not been identified as a possible biomarker related to CRC or as a biomarker in subjects suffering from CRC.
While, the main advantages of the technology described are as follows:
- The device developed allows a reliable, effective, reproducible and fast analysis of VOCs (biomarker compounds) in solid and/or semi-solid samples.
- It has good sensitivity and selectivity.
- It is a non-invasive ex vivo diagnostic methodology for CRC.
- Useful for a very large number of subjects.
- Environmentally friendly use.
- The sorbent used can be reused after a stage after adequate cleaning, which improves its economic profitability and its use at a commercial level.
Stage of development
Under development/lab tested
Partner sought
- Type of partner sought: Companies
- Specific area of activity of the partner: medical diagnostic laboratories; analytical instrumentation manufacturers.
- Task to be performed:
* In the license agreement: to buy a license for the technology, to produce a commercial prototype and make its validation in real scenarios, and to introduce it into the market.
* In the technical cooperation agreement: to provide their expertise in order to collaborate with the scientists to develop new applications for other types of diagnostics. The company should identify technical requirements and/or market and client’s needs in order to carry out further technical development so that the market readiness will be increased and the technology could be commercially exploited.